examples/a2/reuse_calibration.py#
1# Copyright (c) Acconeer AB, 2025-2026
2# All rights reserved
3
4from acconeer.exptool import a2
5
6
7"""
8First session - Setup session without calibration
9 Sensor will calibrate during setup
10"""
11
12with a2.Client.open() as client:
13 client.setup_session(a2.SessionConfig.default())
14
15 calibration = client.calibration
16
17 """
18 client.calibrations_provided will be equal to False since calibration was not provided
19 """
20 print(
21 f"Setup without provided calibration ==> calibration_provided = {client.calibration_provided}"
22 )
23
24 client.start_session()
25
26 result = client.get_next()
27 print("client tick:", result.tick)
28
29 client.stop_session()
30
31
32"""
33Second session - Setup session with calibration
34 Sensor will reuse calibration and not calibrate during setup
35"""
36
37with a2.Client.open() as client:
38 client.setup_session(a2.SessionConfig.default(), calibration=calibration)
39
40 """
41 client.calibrations_provided will be equal to True since calibration was provided
42 """
43 print(
44 f"Setup with provided calibration ==> calibration_provided = {client.calibration_provided}"
45 )
46
47 client.start_session()
48
49 result = client.get_next()
50 print("client tick:", result.tick)
51
52 client.stop_session()